-40%
USA Geniune S&A CW-5200DH Industrial Water Chiller for 130 CO2 Glass Laser Tube
$ 340.97
- Description
- Size Guide
Description
S&A CW-5200DH Industrial Water Chiller (AC 1P 110V 60Hz)1400W cooling capacity,
5
0W DC
pump
, 1 outlet and 1 inlet.
The water temperature is able to be adjusted.
for One
8KW
Spindle / Welding Equipment
One
130-150W
CO2 Glass Laser Tube Cooling, 0.93HP
L
ocal pick up is available.
Door to Door Servi
ce.
2
4-hour technical support by email or calling.
3 years warranty
S&A CW-5200DH
industrial water chiller
(AC 1P 110V 60Hz) for One 8KW Spindle/Welding Equipment/One 130-150W CO2 Glass Laser Tube Cooling, 0.93HP
Features
• 1400W cooling capacity; optional
environmental
refrigerant;
• Compact size, long working life and simple operation;
• ±0.3°C precisely temperature control;
• The intelligent temperature controller has 2 control modes, applicable to different applied occasions; with various setting and display functions;
• Multiple alarm functions: compressor time-delay protection, compressor overcurrent protection, water flow alarm and over high / low temperature alarm;
• Multiple power specifications; CE approval; RoHS approval;
• Optional heater and water filter.
Description
Our CW-5200 is refrigeration type industrial
Water Chiller
of 1400W cooling capacity. It’s mainly used to have the heat generated during the laser device working that gone through the refrigerating cycle in compressor refrigeration system and eventually transferred to the air. The water temperature is able to be adjusted. There are 2 specifications as 1 water outlet / inlet and dual water outlet / inlet, applicable to cool single laser glass tube.
Have design patent Certificate, CE and RoHS Certif
icate.
This Water Chiller has been sold largely to Europe, South America, Asia and other markets.
Economic cooling equipment, easy to install and operate, compact and easily movable.
Our industrial
water chillers
are popular for its
2 temperature control modes
as constant temperature and intelligent temperature control. Under intelligent mode, the water temperature is adjusted according to ambient temperature. With that 1 key solution, customers no longer need to worry about the water temperature adjustment of seasonal changes.
Model
CW-5200DH- US
Power Supply
AC 110V, 60Hz
Current
4.5~6.5A
Compressor Power
0.68KW
0.93HP
Refrigerating Capacity
5186Btu/h
1.52KW
1307Kcal / h
Refrigerant
R-22 / R-134a / R-410a
Refrigerant Charge
350g
Precision
±0.3°C
Tank Capacity
6L
Reducer
Capillary
Protection
Over current protection for compressor, flow alarm, over temperature alarm
Pump Power
0.03KW
Maximum Flow
13L / min
Maximum Pumping Lift
12M
Inlet and Outlet
External Φ10mm brass connector
Net Weight
26kg
Gross Weight
29kg
Product Dimension
22.8" x 11.4" x 18.5" (580 x 290 x 470mm)
Package Dimension
27.6" x 16.9" x 22.8" (700 x 430 x 580mm)
Alarm function
E1
E2
E3
E4
E5
Over high room temperature
Over high water temperature
Over low water temperature
Room temperature sensor failure
Water temperature sensor failure
Remark:
When alarm occurs, the error code and the temperature will be alternately displayed.
In alarming state, the alarm sound could be suspended by pressing any button, but the alarm display
remains until the alarm condition is eliminated.
Thermostat parameters list:
Order
Code
Project Setting
Range
Factory
Setting
Notes
1
F0
Temperature setting
F9 – F8
25
Constant temperature control effecting
2
F1
Temperature difference values
-15 - +5
-2
Intelligent control effecting
3
F2
Cooling hysteresis
0.1 – 3.0
0.8
4
F3
Way of control
0 - 1
1
1: intelligent
0: constant temperature
5
F4
Alarm for over high water temperature
1 - 20
10
6
F5
Alarm for over low water temperature
1 - 20
15
7
F6
Alarm for over high room temperature
40 - 50
45
8
F7
Password
00 - 99
8
9
F8
The allowed highest water temperature
F0 - 40
30
10
F9
The allowed lowest water temperature
1 – F0
20
Details:
Temperature controller panel:
Under normal circumstance, the new intelligent temperature controller does not need to adjust the controlling parameters.
It will self-adjust controlling parameters according to room temperature, guaranteeing to meet cooling requirements for machines.
Alarm Function’s Description:
Flow alarm and output ports:
In order to guarantee the equipment will not be damaged while cooling water circulation is out of control, CW-5200series chillers possesses an unique low flow alarm protection.
T
he cooling water circulation loop alarm causes and the work of the state table
Normal Flow
Indicator
Flow Alarm
Indicator
Buzzer
Output Ports
Hi, H2
Output Ports
H1, H3
Circulating pump works properly
ON
OFF
NOT RING
DISCONNECTION
BREAKOVER
Blocked cooling water circulation loop
OFF
ON
RING
BREAKOVER
DISCONNECTION
Alarm of water shortage
OFF
ON
RING
BREAKOVER
DISCONNECTION
Faulted circulating pump
OFF
ON
RING
BREAKOVER
DISCONNECTION
Power interruption
/
/
/
BREAKOVER
DISCONNECTION
Note:
The flow alarm is connected to the normally open relay and normally closed relay contacts, requiring operating current less than 5A, working voltage less than 300V.
Industrial cooling machine’s installation is very simple, the new machine for the first time using, you can install it as following steps.
A.
Open the package to check if the machine is intact and all the necessary
Accessories
are completed.
B.
Open the injection port to feed cooling water.
Observing the water level gauge and adding water slowly, be careful not to have the water overflowed! For the cooling of carbon steel equipment, the water should be added an appropriate amount of anti - corrosion agentia. Working in cold north area, it’s better to use noncorrosive antifreeze fluid.
C.
According to system conditions, please connect the water inlet and outlet pipe well.
D.
Plug in power, turn on the power switch. (Do not start up without water in the water tank!)
(1) Power switch turned on, the circulation pump of the chiller starts working. The first time of operating may cause more bubbles in the pipe leading to a flow alarming occasionally, but running for a few minutes later, it will go back to normal.
(2) After the first boot, you must immediately check whether the water pipe leaks.
(3) Power switched on, if the water temperature is below the set figure, it is normal that fans and other components of the machine do not work. The temperature controller will automatically control the working conditions of the compressor, magnetic valve, fans and other parts based on the set controlling parameters.
(4) As it takes a longer time to start the compressor and other components, according to different conditions, the time is range from seconds to minutes, so do not turn off the power and again on frequently.
E. Check the water level in the water tank.
The first startup of the new chiller empties the air in the water pipe, leading a slight water level decline, but in order to keep the water level in the green area, it’s allowed to add adequate water again. Please observe and record the current water level, and inspect it again after the chiller running for a period of time, if the water level drops obviously, please re-inspect the water pipeline leakage.
F.
Adjust parameters of temperature controller.
CW-5200 series use an intelligent thermostat. Normally users do not need to adjust it. If it is really necessary, please refer to “Operating status and parameters adjustment.”
One of the differences between the CW5200 water tank and the cw3000 tank lies in that the CW5200 water tank can keep the water at a uniform temperature. Its cooling function can keep the temperature at a certain value, which can be adjusted manually. All the parameters related to the water tank have been set as the correct value by our company before delivery. The user may refer to the parameter instruction manual of the water tank for detailed description on the parameters. It is strongly suggested that the user should not change the parameters without authorization. Our company accepts no responsibility for any insolvable problems caused by the user’s unauthorized changing of parameters
Maintenance
Cooling machine used in long term, you should open the machine and clean the dust in order to ensure good heat dissipation. You can use non – corrosive antifreeze if you are in the northern cold regions.
Cautions
1. Please ensure that the power supply and electrical outlet are in good contact and the earth wire must be firmly grounded! Although the average operating current of the chiller is small, but the instantaneous operating current could be up to 6 ~ 10amps sometimes (The instantaneous operating current of models of AC110V power supply are possible to be up to 10 ~ 15amps).
2. Please make sure there is a stable and normal voltage for the working chiller! As the refrigeration compressor is more sensitive to the power supply and voltage, so the operating voltage of our standard product is of 200 ~ 250V (110V model
is of 100 ~130V). If you do need a wider operating voltage range, customization is available for us.
3. To protect the pump, it’s strictly forbidden to run the chiller without having water in the storage water tank! The new machine is packed after draining whole water in the tank, so please make sure the tank has water inside before machine starting, otherwise it’s easily to have the pump damaged. When the water level is below the green (NORMAL) range of the water level gauge, the cooling capacity of our chiller will go down slightly. Hence please ensure the water level is within the green (NORMAL) range. To drain through circulating pump is strictly prohibited!
4. Please be sure that the air inlet and air outlet are in good ventilation! There must be at least 30cm from obstructions to the air outlet which is in the back of the cooler, and should leave at least 8cm between obstructions and the side air inlet.
5. The filter screen must be regularly cleaned! It’s essential to unpick and wash the dust gauze, or the serious blockage will cause breakdown to the chiller.
6. Please pay attention to the effect of the condensate water! With greater ambient humidity, when the water temperature is lower than the ambient temperature, the condensate water will generate on the surface of water circular pipes and the cooled components. If above circumstance appears, it is recommended to set a higher water temperature or keep pipes and cooled parts warm.
Application:
1.CW-5200 industrial water chiller cool for a single 8KW spindle
2.CW5200 water chiller cool for 2 x 100W laser tube
3.CW5200-water-chiller-cool-for-cnc-machining-center-lathe
4.CW5200-water-chiller-for-cooling-argon-arc-welding-clamp
5.CW5200-water-chiller-cool-for-lab-vacuum-pump
6.CW5200-water-chiller-cool-for-SYNRAD-RF-metal-lasers
7.CW5200-water-chiller-cool-for-blender
Quality Report:
Wooden Box: There is total one carton box.
Machine Dimension
22.8" x 11.4" x 18.5" (580 x 290 x 470mm)
Machine Weight
57.2ib (26kg)
Package
Carton box
Packing Size
27.6" x 16.9" x 22.8" (700 x 430 x 580mm)
Gross Weight
63.8ib (29kg)
Packing list:
CW-5000 water chiller machine
1 set
Power cable
1 pc
Connection hose
1 pc
Sealing washer
2 pcs
250V/2A spare fuse
(Mounted on the power socket
interface within the insurance reserve)
1 pc
User manual
1 pc
Alarm signal output plug
1 pc
cooling water additive
1 / 0 bottle
P.S.:
cooling water additive is forbidden by express company, so we could not put it into the package. You can buy it from local.
Caution:
The appliance is not to be used by children or persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge, unless they have been given supervision or instruction, children supervised not to play with the appliance!
Package: